Clinical lab startup checklist

Clinical Lab Startup Checklist: What to Have Before Testing

A short checklist of what a new clinical laboratory needs in place before it reports patient results.

Short answer: Before testing patient specimens, a new clinical laboratory needs a legal entity and compliant site, a qualified laboratory director and staff, a CLIA certificate from Form CMS-116, any state license, and a working quality system with verified methods, SOPs, QC and proficiency testing. The full guide is on soundlabconsult.com.

Checklist

  • Legal entity, EIN and NPI
  • Site lease, layout, biosafety and OSHA plans
  • Test menu and CLIA complexity decided
  • Qualified laboratory director (42 CFR Part 493 Subpart M)
  • Technical staff qualification files; Form CMS-209 ready
  • Form CMS-116 filed with the state agency; fee coupon paid
  • State license where required
  • Accreditation chosen, if any
  • Instruments and LIS installed; verification or validation done
  • SOPs approved by the director: see the laboratory SOP library
  • QC, proficiency testing enrollment and competency assessments

The 5 core steps behind the checklist

  1. Define scope and test menu: tests, specimen types and CLIA complexity (waived, moderate, high).
  2. Set up the business and site: legal entity, EIN, NPI, space that fits workflow, biosafety and OSHA rules.
  3. Appoint qualified personnel: a laboratory director and staff who meet 42 CFR Part 493 Subpart M.
  4. Obtain credentials: CLIA certificate (Form CMS-116), any state license, and accreditation if you choose it.
  5. Equip the lab and build the quality system: instruments, LIS, method verification, SOPs, QC, proficiency testing and competency.

See also the detailed clinical lab setup checklist, lab go-live checklist and CMS-116 guide.

Official sources

Frequently asked questions

What is the first item on a lab startup checklist?

Decide the test menu and CLIA complexity, because it drives the certificate type, director qualifications, space and equipment.

Is a CLIA certificate enough to start testing?

Not always. Some states also require a state laboratory license, and New York and Washington run CLIA-exempt state programs.

What must be done before the first patient result?

Method verification or validation, director-approved SOPs, QC, proficiency testing enrollment and staff competency.